Primary Aromatic Amines (PAA)

What Are Primary Aromatic Amines?
Primary aromatic amines (PAA) are a group of organic chemical compounds in which a primary amino group is attached to an aromatic ring system. One of the best-known representatives of this group is aniline.
PAA are used in the production of dyes, pigments and various chemical intermediates, among other applications. They can also occur as impurities, reaction products or degradation products, for example from certain azo dyes or polyurethane adhesives.
Primary aromatic amines are of particular concern in materials and articles intended to come into contact with food. Residues may migrate from packaging materials or other food contact articles into food. As some PAA are classified as carcinogenic or mutagenic, their reliable analytical determination is particularly important.
PAA Analysis at a Glance
•︎ Reliable determination of PAA in a wide range of sample matrices
•︎ Precise quantitative analysis using modern LC-MS/MS technology
•︎ Support for quality control and compliance with regulatory requirements
•︎ Food packaging
•︎ Cosmetics
•︎ Recycled plastics
•︎ Paper and cardboard
•︎ Kitchen utensils
•︎ Textiles and other consumer products
Where Can Primary Aromatic Amines Occur?
Primary aromatic amines can be found in various materials and consumer products. Their occurrence depends primarily on the raw materials, colorants and manufacturing processes used.
Relevant product groups include:
- Food packaging: Printed plastic packaging, films and other packaging materials containing colorants or adhesives.
- Recycled plastics: Plastic materials containing post-consumer recyclate (PCR), where contaminants from previous applications may enter the recycling process.
- Paper and cardboard: Printed food contact materials such as napkins, bakery bags or packaging cartons.
- Kitchen utensils: Articles made from certain plastics, particularly polyamide, which may release PAA under specific conditions.
- Textiles and other consumer products: Dyed or printed materials in which certain azo dyes may lead to the release of aromatic amines.
With the increasing use of recycled plastics, testing for PAA is becoming even more important. Particularly for food contact materials, recycling processes must ensure that potential contaminants are sufficiently removed.
Why Is Testing for PAA Important?
Some primary aromatic amines have properties that are harmful to human health. Certain compounds are considered carcinogenic or mutagenic and are therefore subject to strict regulatory requirements.
The potential migration of PAA from food contact materials is of particular concern. PAA may migrate from packaging or kitchen utensils into food and subsequently be ingested by consumers.
For genotoxic carcinogens, the ALARA principle (As Low As Reasonably Achievable) generally applies. This means that exposure should be reduced as far as reasonably achievable using available technical measures.
Regulatory Requirements for Primary Aromatic Amines
In the European Union, primary aromatic amines are subject to various regulatory requirements. The applicable limits and restrictions depend on the individual substance and the intended use of the material.
For plastic food contact materials, Regulation (EU) No 10/2011 is particularly relevant. It establishes specific requirements for the migration of PAA from plastic materials into food or food simulants.
For certain primary aromatic amines listed in Appendix 8 to Entry 43 of Annex XVII to the REACH Regulation, for which no individual specific migration limit applies, migration is not permitted. These substances must not be detectable at an analytical detection limit of 0.002 mg/kg of food or food simulant for each individual substance.
For other PAA that are not included in this REACH list and for which no specific migration limit has been established, a combined migration limit of 0.01 mg/kg of food or food simulant applies.
Restrictions also exist outside the food contact sector. For example, the European REACH Regulation restricts the use of certain azo dyes that may release carcinogenic aromatic amines under defined conditions, such as in textiles and leather articles.
Furthermore, increasingly low detection limits are becoming a focus of risk assessment. The German Federal Institute for Risk Assessment (BfR) aims to progressively reduce detection limits for certain genotoxic carcinogens, insofar as this is technically and analytically feasible. A long-term target value of 0.15 µg/kg of food has been proposed for migration into food. However, this is not a generally binding legal limit for all PAA.
PAA Analysis at GALAB
GALAB offers comprehensive analytical services for the determination of primary aromatic amines and has expanded its analytical scope to include more than 60 individual substances.
This broad range of parameters allows numerous compounds within this substance group to be analyzed and potential contaminants to be assessed individually. This is particularly important for complex materials in which different PAA may occur simultaneously.
Testing is especially relevant for manufacturers of food contact materials, packaging producers and companies in the plastics and recycling industries.
Reliable PAA analysis enables the assessment of potential residues and migration, as well as the verification of regulatory and product-specific requirements.
Comprehensive testing is particularly valuable for recycled plastics. Due to the diverse origins of recycled materials, substances that were not originally intended to be present in the plastic may enter the recycling stream. The determination of primary aromatic amines can therefore make an important contribution to assessing material purity and qualifying recycling processes.
With its expanded analytical scope, GALAB supports companies in identifying potential contamination, improving quality control and verifying the safety of their products throughout the supply chain.
Interested in PAA testing?
Get in touch with our experts to discuss your testing needs and receive a tailored quote.
Parameters & Analytical Methods
-
State-of-the-Art Analysis
We constantly update our spectrum of parameters to the latest developments in the food analysis sector and offer state-of-the-art analytical methods for the safety of your products.
-
Comprehensive multi-methods
We are constantly expanding our range of services in order to be able to guarantee you a comprehensive range of analyses. We offer multi-methods for mycotoxins, dioxin analysis or molecular biological analysis for GMOs and allergens. The GALAB Pesticide500Plus® multi-method can even be used for difficult matrices such as spices and herbs.
-
Constant development
If you cannot find the parameter/analysis you are looking for here, please do not hesitate to contact us. Our research and development department implements your requirements and specifications cost-efficiently and with a high quality standard.
-
Quality Policy
GALAB Laboratories has implemented a quality management system to allow for optimum service for their customers. It is our goal to establish close relations to customers by customer satisfaction. Therefor quick reactions to customers’ specific needs as well as considerations for quality demands of the market are necessary. We strive to provide comprehensive and professional advice to our customers. Learn more
Get in touch, we will help you.